شركة لوجستية عالمية
RHH RHW RHW-2
♦ Conductor: Bare Copper
♦ Insulation: Cross-Linked Polyethylene (XLPE)
♦ Insulation Color: Colors or Black with Number
♦ Temperature : 90℃
♦ Nominal Voltage: 600 V
RHH / RHW / RHW-2 cables are underground Service Entrance Cable. 600 Volt. Copper conductors. Cross-Linked Polyethylene (XLP) Insulation. High-Heat, Moisture, and Sunlight Resistant. Sizes 6 through 4/0 AWG Also Rated SIS. They are used with conduit as specified in the 2011 National Electrical Code. When used as Type USE-2, conductor is suitable for use as underground service entrance cable for direct burial at conductor temperatures not to exceed 90° C. When used as RHH, conductor temperatures shall not exceed 90°C in dry locations. When used as RHW-2 or USE-2, conductor temperatures shall not exceed 90°C in wet or dry locations. Voltage rating for RHH or RHW-2 or USE-2 conductors is 600 volts.Welcome to inquiry.
وصف |
RHH / RHW / RHW-2 |
موصل: |
stranded fine bare copper |
عازلة: |
Cross-Linked Polyethylene (XLPE) |
لون العزل |
أطلب قإد |
درجة الحرارة المقدرة |
90 |
الفولطية: |
600 الخامس |
اختبار الجهد: |
3000 فولت |
الحد الأدنى من نصف قطر الانحناء: |
8 د |
معيار |
UL44 |
معلومات تقنية
AWG |
Conductor O.D. |
سماكة العزل |
OD كابل |
|||
INCH/MM |
INCH/MM |
INCH/MM |
||||
14 |
0.07 |
1.78 |
0.045 |
1.14 |
0.17 |
4.32 |
12 |
0.09 |
2.29 |
0.045 |
1.14 |
0.19 |
4.83 |
10 |
0.12 |
3.05 |
0.045 |
1.14 |
0.21 |
5.33 |
8 |
0.15 |
3.81 |
0.06 |
1.52 |
0.27 |
6.86 |
6 |
0.18 |
4.57 |
0.06 |
1.52 |
0.31 |
7.87 |
4 |
0.23 |
5.84 |
0.06 |
1.52 |
0.36 |
9.14 |
3. ميزة RHH / RHW / RHW-2 Cable
1)Abrasion, moisture, heat, and sunlight resistant
2) ROHS2.0 & REACH Compliant
3)UL Standard 44 for RHH or RHW-2 ; UL Standard 854 for USE-2
4. تفاصيل ملف RHH / RHW / RHW-2 Cable
1) When used as Type USE-2, conductor is suitable for use as underground service entrance cable for direct burial at conductor temperatures not to exceed 90° C.
2) When used as RHH, conductor temperatures shall not exceed 90°C in dry locations
3) When used as RHW-2 or USE-2, conductor temperatures shall not exceed 90°C in wet or dry locations
4) العلامة التجارية: أنيت
5 التغليف والتسليم
1) تفاصيل التغليف:
يتم تحديده حسب الكمية والمتطلبات التي تشتريها. يمكن التفاوض عليها.
2) المنفذ: شنغهاي ، نينغبو
التسليم: عن طريق البحر ، عن طريق الجو ، عن طريق التعبير.
6 التعليمات
Q: What is XLPE material?
A: XLPE or Cross-linked polyethylene is a thermoset insulation material. Crosslinking polymers is a process which changes the molecular structure of the polymer chains so that they are more tightly bound together and this crosslinking is done either by chemical means or physical means.
س: لماذا يجب أن تختار شركتك كشريك تجاري؟
ج: (1) لدينا أكثر من 10 سنوات من تصنيع وتصدير الكابلات ، وشهادات كاملة للكابلات.
(2) قدرة البحث والتطوير لدينا قوية وموظفونا مدربون جيدًا ومهرة.
(3) لدينا جودة كاملة للمواد والإنتاج. موردي المواد الثابتة والمؤهلين.
(4) استجابة سريعة للاقتباس أو خدمة العملاء.
اتصل بنا
Follow us: